WARNING: DRC OUT OF DATE on this layout.
******************************************
---- Photoplot outline rectangle not found ... using drawing extents

Results from parameter file ...
    DEVICE-TYPE           GERBER_RS274X
    OUTPUT-UNITS          INCHES
    FILM-SIZE             24000 16000
    FORMAT                5.3
    ABORT-ON-ERROR        NO
    SCALE                 1
    SUPPRESS-LEAD-ZEROES  YES
    SUPPRESS-TRAIL-ZEROES NO
    SUPPRESS-EQUAL        YES
    UNDEF-APT-CONT        NO
WARNING: for raster artwork formats, artwork accuracy must be
  at least one place greater than the database accuracy, up
  to the maximum accuracy allowed by the selected output format.
  Increase the accuracy by increasing the "Decimal Places" in
  the FORMAT section of the artwork parameters and then rerun
  artwork.
  The current output is rounding down the data.  Failure to change
  the format may result in inaccurate arc coordinates in the output
  files and possible shape/void plotting failures.

================================================================
     PROCESSING FILM < gnd02 >
     TO FILE < E:/letou/nvp2b/gnd02.art > ...
================================================================
  FILM PARAMETERS :
  ---------------------------------------------------------
  Undefined line width                0.00
  Suppress shape fill on neg film     NO
  Mirror code                         NONE
  Rotate angle                        NONE
  Offset x:                           0.00
  Offset y:                           0.00
  Plot negative                       YES
  Suppress unconnected internal pads  NO
WARNING: Photoplot window (50000 x 50000) exceeds film size (24000 x 16000)
          stated in parameter file.
    WARNING: Film contains DRC error(s).

  APERTURES USED:
  ---------------------------------------------------------
  TYPE       SIZE/NAME                   ROT   MIRROR MODE
  ---------------------------------------------------------
  CIRCLE     0.02700                                  CLEAR
  CIRCLE     0.03200                                  CLEAR
  CIRCLE     0.06200                                  CLEAR
  CIRCLE     0.06600                                  CLEAR
  CIRCLE     0.07000                                  CLEAR
  CIRCLE     0.08200                                  CLEAR
  CIRCLE     0.09000                                  CLEAR
  OBLONG     0.05600     x 0.07800      90.000 NO     CLEAR
  FLASH SYM  8                           0.000 NO     CLEAR
  FLASH SYM  32                          0.000 NO     CLEAR
  FLASH SYM  125                         0.000 YES    CLEAR
  FLASH SYM  72                         90.000 NO     CLEAR
  FLASH SYM  8                          90.000 NO     CLEAR
  FLASH SYM  32                         90.000 NO     CLEAR
  FLASH SYM  86                         90.000 NO     CLEAR
  FLASH SYM  8                         180.000 NO     CLEAR
  FLASH SYM  105                       180.000 NO     CLEAR (undefined)
  FLASH SYM  32                        180.000 NO     CLEAR
  FLASH SYM  8                         225.000 NO     CLEAR
  FLASH SYM  32                        270.000 NO     CLEAR
  FLASH SYM  8                         270.000 NO     CLEAR

    ERROR: aborting film - Undefined aperture symbol, cannot continue.
           See APERTURES USED table in this file for symbols to provide.
Error in gnd02--halting output.  Artwork file not generated.
*** ERROR with gnd02


------------------------------------------------------
SUMMARY:
    *** ERROR with gnd02
ARTWORK Error

你还是先执行下DRC检查吧。

你没画Photoplot outline ,setup->area->Photoplot outline ,画个框框框住你的板子~

你没有画outline,缺少这个设置,DRC校验错误。

outline  Photoplot outline  都有画 还是报告同样的错误,那个说 执行DRC 的 朋友,我当 你是和我开玩笑

真晕。首先,你把artwork和nc parameters里面的精度设置成一致的(调整5:5),然后在artwork窗口中,对应每一个art都在右边把Undefined line width设置成0.10或0.20。
再试试。

你可以运行tools-->database check,点击performances advisor。看看报告中给出的警告或错误,对应修改。

回复,BLUEKINGXQ,我的设置本身就是这样的,还是报错

DB check 后没有报错,应该都不是这些原因

回复 9# allegro_ren

    你原来的设置肯定不是我说的,你看看你贴出来的log文件内容就知道了。db check不要用check那个按钮,用我说的那个。

已经解决了,是没有找到FLASH SYM  105                       180.000 NO     CLEAR (undefined)
这个 flash sym的 热焊盘,感谢几位朋友的帮忙

祝贺你解决问题,虽然俺没帮上忙。

FLASH SYM  105 ,这个没有定义代码.

你是怎么找到哪个焊盘用了这个flash的啊?
我也出现了这样的问题,但是找不到是哪个焊盘使用的?
谢谢