- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
HFSS15: Assign Impedance Boundaries for HFSS-IE
The impedance boundaries for HFSS-IE are derived assuming the fields decay to zero inside the object on which the boundary is assigned.
Note | For HFSS-IE impedance boundaries assume the interior E-field decays to 0 and thus can not be used as an approximation for a transmission condition through a thin dielectric sheet. |
1. Select a surface on which to assign the boundary, right-click Assign Boundary>Impedance to bring up the Impedance Boundary dialog box.
2. Set the fields in the dialog box and click OK.
Note | HFSS-IE does not support infinite ground plane for impedance boundaries. |
HFSS 学习培训课程套装,专家讲解,视频教学,帮助您全面系统地学习掌握HFSS
上一篇:Applying a New View Orientation
下一篇:Applying a Tuned State to a Design