- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
HFSS15: Specifying a Linear Count of Frequency Points
1. In the Edit Sweep dialog box, click Linear Count in the Type pull-down list.
2. In the Start text box, type the starting frequency of the frequency sweep.
HFSS solves the solution beginning with the frequency entered in the Start box and ending with the frequency entered in the Stop box. For Fast and Interpolating sweeps, setting the initial value to 0 enables the DC Extrapolation option.
3. In the Stop text box, type the ending frequency of the frequency sweep.
4. In the Count text box, type the number of points in the sweep. The count value includes the start and stop values.
HFSS will divide the frequency range into the count you specify and solve each frequency point in the count.
To view a table of the frequencies and count, click the Display button. If the list of frequencies is longer than the visible display, you can use a scroll bar to view the list to the end of the count.
5. For Fast sweeps, select Save Fields if you want to save the calculated 3D field solutions associated with all port modes at the chosen frequencies.
For Discrete sweeps, select Save Fields (All Frequencies) if you want to save the calculated 3D field solutions associated with all port modes at the chosen frequencies.
If want to save the fields for just one or a few Discrete sweep frequencies, click the Display button to show a table of frequencies, and select Single Points from the Type pull-down list. This disables the Save Fields checkbox for the entire sweep, and adds a Save Fields column with a checkbox for each frequency. You can select the Save Fields check box for the desired frequency, or click the Save Fields column header to check or uncheck all frequencies.
For Discrete sweeps, HFSS always solves the frequencies from highest to lowest.
HFSS 学习培训课程套装,专家讲解,视频教学,帮助您全面系统地学习掌握HFSS
上一篇:Specifying the Frequency Points to Solve
下一篇:Specifying the Hard Memory Limit